Biodegradable metals are a class of metal that when implanted will gradually degrade and be completely resorbed. The degradation products are then metabolized by the human body.
Author: megagen
Cost-Effective Protection
collafleece® is a cost-effective alternative to barrier membranes during sinus floor elevations for the protection of the Schneiderian membrane. It can also be used to protect barrier membranes from fast bacterial resorption when an exposure is likely.
Easy Application/Handling
A dry application of collafleece® is recommended because pre-hydration may impair its hemostatic properties. At the defect site, the fleece soaks up blood very quickly but maintains its integrity. A direct fixation by sutures/pins is not possible, but also not necessary. Indirect fixation, on the other hand, by cross- or holding sutures could help keeping the fleece in place e.g. in extraction sockets or at soft tissue harvesting sites.
Prevention of Bleeding Hemostatic Compromised Patients
Medication with anticoagulant drugs (i.e. heparin or warfarin) poses a risk for patients of bleeding following tooth extraction. Local hemostatic agents like collagen fleeces can prevent postoperative bleeding without the need to pause the anticoagulant therapy. A retrospective study with 200 anticoagulated patients showed a very low rate of bleedings following application of collagen sponges with a similar composition (collacone®).
Natural Hemostatic Function of Collagen
Damage to the blood vessel wall leads to subendothelial collagen release. The collagen directly or indirectly interacts with the surface receptors on thrombocytes. The binding of collagen initiates a reaction cascade leading to transformation and aggregation of the thrombocytes. Additionally, the thrombocytes are cross-linked by fibrinogen. The resulting (white) thrombus initially stabilizes the wound. Accordingly, collagen membranes and sponges support the formation of a blood coagulum and contribute to a rapid stabilization of the wound area. Due to their hemostatic effect, collagen sponges and cones can be used for stabilization of biopsy harvesting sites or covering of minor oral wounds and extraction sockets, respectively.
High Safety
collafleece® is produced in a certified process from the porcine dermis. The unique manufacturing process provides a safe and cell-free product that is regulated according to the EC guidelines. Its natural hemostatic effect and the fast resorption making collafleece® an excellent medical device for the treatment of oral wounds.
Combination of mucoderm® with Enamel Matrix Proteins
mucoderm® supports the maintenance and thickening of gingival tissue, which can be particularly advantageous in thin biotypes. The additional application of Straumann® Emdogain® during recession coverage with mucoderm® can:
• improve the qualitative attachment;
• stimulate angiogenesis and thus improve the revascularization and integration of mucoderm®;
• increase the quantity of keratinized tissue, which can be beneficial in case of lack or absence of keratinized gingiva 14.
Tissue Integration, Revascularization and Degradation
mucoderm® is characterized by a porous collagen structure, visualized by the innovative synchrotron-based X-ray tomography: Synchrotron-based X-ray tomographic microscopy for visualization of three-dimensional collagen matrices.

Synchrotron-based x-ray image showing the porous structure of mucoderm®
This unique structure makes mucoderm® an ideal scaffold for ingrowth of blood vessels and cells and promotes fast tissue integration and revascularization. Tissue integration and degradation were analyzed in an animal (rat model) study of Prof. Daniel Rothamel4. After only two weeks, mucoderm® shows an extensive ingrowth of blood vessels as well as an inflammation-free healing with superficial cell invasion. In the following four to eight weeks, a continuous degradation with increasing homogeneous cell distribution can be observed. After eight weeks, still 20% of the original matrix volume is available as a scaffold for the formation and reorganization of connective tissue. After twelve weeks, mucoderm® is almost completely replaced by newly formed connective tissue.
Native Collagen Structure
mucoderm® is a native collagen matrix, meaning that the natural properties of the original tissue (dermis) are preserved during the production process. This is the basis for its superior handling properties such as tear resistance and dimensional stability. Preservation of the natural structure is also the reason that mucoderm® structure strongly resembles the architecture of the human dermis1, making the matrix a suitable alternative to autologous gingival transplants.
Highest Safety
The particular, certified multi-stage cleaning process of mucoderm® effectively removes all non-collagenous proteins and cells as well as potential immunogens, bacteria and viruses. Hence, mucoderm® is an absolutely safe and pure collagen type I and III matrix. mucoderm® is a medical device regulated according to EC-Guidelines. Manufacturing of mucoderm® is subject to a quality control system based on international standards (e.g. EN ISO 13485), and is regularly audited by the notified body and authorities.